Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGS243HRAA0AAAA — OEM Furnace Control | Ships Today
ICP

ICP Control Board Kit for RGS243HRAA0AAAA — OEM Furnace Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit is the brain of your ICP Tempstar Heil RGS243HRAA0AAAA gas furnace. The integrated furnace control manages the entire heating sequence — it reads the thermostat call, runs the inducer and pressure switch check, energizes the igniter, opens the gas valve, sequences the blower, and monitors flame and limit safeties. When the board fails you may see no response to a heat call, erratic blower behavior, repeated lockouts, or flashing diagnostic LED fault codes. This complete kit is a direct-fit replacement that restores full, safe furnace operation.

Specifications

Spec Value
OEM Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Function Ignition, Blower, and Safety Control

Compatibility

Engineered for the ICP Tempstar Heil RGS243HRAA0AAAA gas furnace and related RGS243-series models. Confirm the board part number and connector layout match your existing control before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the blower/control compartment service panel.
  3. Document — Photograph every connector and wire harness position before disconnecting — this is critical for the many low- and line-voltage plugs.
  4. Remove — Unplug all harnesses, release the board standoffs or screws, and remove the old board.
  5. Install — Mount the new board and reconnect each harness exactly per your photos.
  6. Test — Restore power and run a full heat cycle, confirming proper ignition, blower timing, and no fault codes.

Signs You Need a Replacement

  • No response to a thermostat heat call
  • Flashing diagnostic LED fault codes
  • Erratic blower or inducer operation
  • Repeated lockouts with no obvious cause
  • Visible scorching or burnt components on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS243HRAA0AAAA — OEM Furnace Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS243HRAA0AAAA — OEM Furnace Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS243HRAA0AAAA — OEM Furnace Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online