Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGS240SSFA0AAAA — Furnace Ignition Control | Ships Today
ICP

ICP Control Board Kit for RGS240SSFA0AAAA — Furnace Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM control board kit (OEM part number 1183618) for the ICP/Heil/Tempstar RGS240SSFA0AAAA gas furnace. The integrated furnace control board is the brain of the system — it sequences the inducer, igniter, gas valve, and blower, monitors safety circuits such as limit and flame sensing, and manages the timing of each heating cycle. When the board fails you may see no response to a thermostat call, blower or inducer that will not start, flashing diagnostic LED fault codes, or intermittent lockouts. This kit ships with the board and the hardware needed for a clean OEM replacement.

Specifications

Spec Value
OEM Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Heil / Tempstar
Function Ignition, Blower & Safety Sequencing
Fits Model RGS240SSFA0AAAA

Compatibility

Supplied as a direct OEM kit for the ICP RGS240SSFA0AAAA and shared across Heil, Tempstar, and Comfortmaker RGS-series furnaces using this control. Match the OEM part number and connector layout to your original board before installing.

Installation Guide

  1. Safety First — Disconnect power and shut off gas; verify zero voltage with a multimeter.
  2. Access — Remove the control compartment service panel.
  3. Document — Photograph every connector and wire location on the old board.
  4. Remove — Unplug all harnesses, release the mounting standoffs, and lift out the failed board.
  5. Install — Seat the new board on its standoffs and reconnect each harness exactly per your photo.
  6. Test — Restore power and gas, run a full heat cycle, and confirm no fault LED codes.

Signs You Need a Replacement

  • No response from the furnace on a thermostat call for heat
  • Flashing diagnostic LED fault codes on the board
  • Inducer or blower fails to energize in sequence
  • Repeated unexplained lockouts or short cycling

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS240SSFA0AAAA — Furnace Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS240SSFA0AAAA — Furnace Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS240SSFA0AAAA — Furnace Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online