Overview

This OEM control board kit (part #1183618) is the integrated furnace control that orchestrates the entire heating sequence in your ICP RGS240LSEA0AAAA package unit. It manages the inducer motor, hot surface igniter, gas valve timing, blower operation, and all safety interlocks including limit and flame-sensing circuits. When a control board fails, the result is erratic behavior — no ignition, blower running constantly, or the unit ignoring thermostat calls entirely. This kit ships with the mounting hardware and instructions needed for a complete replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP
Function Ignition, Blower & Safety Sequencing
Fit OEM Direct Replacement Kit

Compatibility

Direct-fit replacement for ICP / Tempstar / Heil RGS240LSEA0AAAA package units and compatible RGS240-series gas/electric models using the same integrated control platform.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off gas; verify zero voltage with a multimeter.
  2. Access — Remove the furnace control compartment panel.
  3. Document — Photograph every connector and wire location on the existing board before removing anything.
  4. Remove — Unplug all harnesses, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board from the kit and reconnect each harness exactly per your photos.
  6. Test — Restore gas and power, then verify the full ignition and blower sequence on a heat call.

Signs You Need a Replacement

  • No response to thermostat heat or cool calls
  • Blower runs continuously or won't start
  • Repeated ignition lockouts with no component fault found
  • Visible scorching, corrosion, or failed relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS240LSEA0AAAA — Furnace Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS240LSEA0AAAA — Furnace Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS240LSEA0AAAA — Furnace Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.