Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGS240LRAA0AAAA — OEM Furnace Board 1183618 | Ships Today
ICP

ICP Control Board Kit for RGS240LRAA0AAAA — OEM Furnace Board 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM control board kit (part number 1183618) for the ICP / Tempstar / Heil RGS240LRAA0AAAA gas/electric package unit. The integrated furnace control board is the brain of the unit — it sequences the inducer, igniter, gas valve, and blower, monitors the safety limits and flame sensor, and stores diagnostic fault codes. When the board fails, the whole unit can go dead or behave erratically. Typical symptoms include no response on a heat or cool call, a blower that runs constantly or never starts, ignition that won't sequence, and diagnostic LEDs that are dark or flashing a hard-fault code. Supplied as a kit, this OEM board restores proper sequencing and safety monitoring and eliminates the intermittent faults caused by a failing control.

Specifications

Spec Value
OEM Part Number 1183618
Description Kit, Control Board
Type Integrated Furnace Control (IFC)
Brand ICP / Tempstar / Heil
Application Ignition, Blower & Safety Control
Fitment OEM Direct Replacement Kit

Compatibility

Direct-fit OEM replacement kit for the ICP/Tempstar/Heil RGS240LRAA0AAAA package unit and related ICP-built equipment that originally used control board kit 1183618. Confirm the board layout, connector count, and mounting standoffs match your original before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter. Shut off the gas supply.
  2. Access — Remove the control/electrical service panel.
  3. Document — Photograph every plug, harness, and jumper position on the old board before disconnecting.
  4. Remove — Unplug each connector, remove the mounting screws/standoffs, and lift out the old board.
  5. Install — Mount the new board, transfer any jumper/DIP settings, and reconnect each harness per your photo.
  6. Test — Restore gas and power, run a full heat and cool cycle, and confirm correct sequencing and no fault codes.

Signs You Need a Replacement

  • No response to thermostat heat or cool calls
  • Blower runs constantly or won't start
  • Ignition sequence stalls or skips steps
  • Diagnostic LED is dark or flashing a hard-fault code

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS240LRAA0AAAA — OEM Furnace Board 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS240LRAA0AAAA — OEM Furnace Board 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS240LRAA0AAAA — OEM Furnace Board 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online