Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGS240LFFA0AAAA – OEM Furnace Board | Ships Today
ICP

ICP Control Board Kit for RGS240LFFA0AAAA – OEM Furnace Board | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ICP control board kit (part #1183618) is the integrated furnace control (IFC) that manages your entire heating sequence: it controls the igniter, gas valve, inducer motor, blower timing, and safety lockouts while monitoring the flame sensor and pressure switches. As the brain of the furnace, a failed board can leave the system completely dead or cause erratic behavior. Common symptoms include a furnace with no response to a heat call, blower or inducer that won't start, repeated lockouts with diagnostic LED fault codes, visible burn marks or scorched relays on the board, or intermittent operation. This kit ships with the components needed for a complete board replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil / Comfortmaker)
Application Gas Furnace Control
Fit OEM Replacement Kit

Compatibility

This control board kit is the factory-specified replacement for the ICP/Tempstar/Heil furnace model RGS240LFFA0AAAA and related ICP-family furnaces using this integrated ignition control. Match your existing board's part number and connector layout before installing, and keep the included instructions for any required jumper or dip-switch settings.

Installation Guide

  1. Safety First – Turn off furnace power and gas, then verify zero voltage with a multimeter.
  2. Access – Remove the furnace control/blower compartment panel.
  3. Document – Photograph every wire harness and connector on the old board before disconnecting.
  4. Remove – Unplug each connector, release the board's standoff clips or screws, and lift it out.
  5. Install – Mount the new board, set any jumpers/dip switches to match your configuration, and reconnect every harness per your photos.
  6. Test – Restore power and gas, call for heat, and confirm a full ignition sequence with no fault codes.

Signs You Need a Replacement

  • No response from the furnace on a call for heat
  • Diagnostic LED showing a control or lockout fault
  • Burnt smell, scorched relays, or visible board damage
  • Intermittent operation or random shutdowns

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS240LFFA0AAAA – OEM Furnace Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS240LFFA0AAAA – OEM Furnace Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS240LFFA0AAAA – OEM Furnace Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online