Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGS240LDEA0AAAA — Furnace Ignition Control | Ships Today
ICP

ICP Control Board Kit for RGS240LDEA0AAAA — Furnace Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part number 1183618) is the factory ignition/integrated furnace control replacement for the ICP / Tempstar / Heil RGS240LDEA0AAAA gas/electric package unit. The control board is the brain of the system — it manages the ignition sequence, inducer and blower timing, flame sensing, safety lockouts, and limit/pressure switch monitoring. When the board fails you may see no heat, a blower that won't start or won't stop, a unit stuck in lockout, or erratic LED fault codes. Supplied as a complete kit with the correct connectors, this OEM board restores proper, code-correct operation without the guesswork of a universal control.

Specifications

Spec Value
Part Number 1183618 (Kit, Control Board)
Type Integrated Furnace / Ignition Control Board
Brand ICP (Tempstar / Heil)
Supplied As Complete Replacement Kit
Fits Model RGS240LDEA0AAAA
Fitment OEM Direct Replacement

Compatibility

Engineered for the ICP / Tempstar / Heil / Comfortmaker RGS240LDEA0AAAA package unit and related RGS240 series gas/electric systems specifying this control board kit. Confirm the board's part number and connector layout against your existing control before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the control/service panel to expose the existing board.
  3. Document — Photograph every plug, harness, and terminal on the old board before unplugging anything.
  4. Remove — Unplug each connector, release the mounting standoffs/screws, and lift out the old board.
  5. Install — Mount the new board on the same standoffs and reconnect every harness exactly per your photo.
  6. Test — Restore power and run a full heat and cool cycle, watching the diagnostic LED for normal operation and no fault codes.

Signs You Need a Replacement

  • No heat or no response on a thermostat call
  • Blower or inducer that won't start, or runs continuously
  • Repeated lockouts or erratic LED fault codes
  • Visible burn marks, corrosion, or cracked solder on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS240LDEA0AAAA — Furnace Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS240LDEA0AAAA — Furnace Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS240LDEA0AAAA — Furnace Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online