Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGS213LSEA0AAAA — Furnace Ignition Control | Ships Today
ICP

ICP Control Board Kit for RGS213LSEA0AAAA — Furnace Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM furnace control board kit (part #1183618) is the central control for your ICP Tempstar/Heil RGS213LSEA0AAAA gas furnace. It sequences ignition, manages blower on/off timing, monitors flame sense, and enforces safety lockouts across the gas valve, igniter, and flame sensor. A failed board commonly results in no ignition, continuous blower operation, short-cycling, or repeated safety lockouts with an error flash code. Genuine OEM boards guarantee correct timing and full compatibility with the furnace's safety circuit.

Specifications

Spec Value
Part Number 1183618
Type Furnace Ignition Control Board Kit
Brand ICP / Tempstar / Heil
Fits Model RGS213LSEA0AAAA
Fitment OEM Replacement

Compatibility

Engineered as the factory replacement for the ICP Tempstar/Heil RGS213LSEA0AAAA gas furnace. Because ICP builds equipment under the Heil, Tempstar, Comfortmaker, and Arcoaire badges, this board may also service equivalent models in those lines — always confirm against your existing board's part number.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower-compartment service panel.
  3. Document — Photograph every wire and connector on the existing board before disconnecting.
  4. Remove — Unplug the wiring harnesses, release the board mounting standoffs/screws, and lift out the old board.
  5. Install — Mount the new board on the standoffs and reconnect every harness exactly per your photos.
  6. Test — Restore power, initiate a heat call, and verify the full ignition sequence and blower operation.

Signs You Need a Replacement

  • Furnace will not ignite or ignores the heat call
  • Diagnostic LED shows a fault flash code or stays dark
  • Blower runs continuously or fails to start
  • Intermittent short-cycling or safety lockouts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS213LSEA0AAAA — Furnace Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS213LSEA0AAAA — Furnace Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS213LSEA0AAAA — Furnace Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online