This is the OEM control board kit (part number 1183618) for the ICP / Tempstar / Heil RGS213LECA0AAAA gas furnace. The integrated furnace control board manages the entire ignition sequence — it powers the inducer, energizes the hot surface igniter, opens the gas valve, monitors the flame sensor and pressure switches, and runs the safety lockouts and blower timing. When this board fails, the furnace usually will not start, locks out after a few attempts, short-cycles, or runs the blower continuously. Because it governs every step of start-up and safety, a faulty board is one of the most common no-heat failures. This genuine OEM kit is a direct, plug-in replacement with the correct firmware and connector layout.

Specifications

Spec Value
Part Number 1183618
Description Kit, Control Board
Type Integrated Furnace Ignition Control
Brand ICP (Tempstar / Heil)
Fits Model RGS213LECA0AAAA
Fitment OEM Direct Replacement

Compatibility

Engineered for the ICP-family RGS213LECA0AAAA gas furnace and shared chassis platforms sold under the Tempstar, Heil, and Comfortmaker brands. Confirm your existing board part number and connector configuration against 1183618 before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment door.
  3. Document — Photograph every wire and connector position on the old board before disconnecting.
  4. Remove — Unplug the harness connectors and low-voltage leads, then remove the board mounting screws or standoffs.
  5. Install — Mount the new 1183618 board, transfer all connectors exactly per your photo, and seat each plug fully.
  6. Test — Restore power and verify a full ignition cycle: inducer, igniter, gas valve, flame proof, and blower.

Signs You Need a Replacement

  • Furnace will not ignite or locks out after several attempts
  • No status LED, or an error flash code indicating board fault
  • Blower or inducer runs continuously or not at all
  • Intermittent no-heat that clears after a power reset

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS213LECA0AAAA — OEM 1183618 Furnace Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS213LECA0AAAA — OEM 1183618 Furnace Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS213LECA0AAAA — OEM 1183618 Furnace Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.