Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGS213HFCA0AAAA — OEM 1183618 | Ships Today
ICP

ICP Control Board Kit for RGS213HFCA0AAAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine ICP / Heil / Tempstar control board kit (OEM part number 1183618) for the RGS213HFCA0AAAA gas furnace. The furnace control board (often called the integrated furnace control, or IFC) is the brain of the system: it sequences the inducer, igniter, gas valve, and blower, monitors limit and pressure switches, manages flame sense, and runs diagnostics and safety lockouts. When the board fails you may see no response on a heat call, a stuck blower, blank or error-flashing diagnostic LEDs, or random lockouts. The kit ships as a complete replacement assembly to restore full furnace operation.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Heil / Tempstar / Comfortmaker)
Application Gas Furnace Ignition / Sequencing Control
Fit OEM Replacement

Compatibility

Designed for the ICP RGS213HFCA0AAAA gas furnace and related Heil, Tempstar, Comfortmaker, and Arcoaire models that use this control board kit. Verify the OEM part number and connector layout against your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control/blower compartment service panel.
  3. Document — Photograph every connector and wire harness on the board before unplugging anything.
  4. Remove — Unplug the harnesses, release the board standoffs, and lift out the old control board.
  5. Install — Mount the new board on the standoffs and reconnect each harness to the matching terminal per your photo.
  6. Test — Restore power, run a full heat cycle, and confirm proper sequencing with no fault codes on the diagnostic LED.

Signs You Need a Replacement

  • No response from the furnace on a call for heat
  • Blower runs constantly or won't run at all
  • Blank, dead, or error-flashing diagnostic LED
  • Random lockouts or incorrect ignition sequencing

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS213HFCA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS213HFCA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS213HFCA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online