Overview

This OEM control board kit (Part No. 1183618) is the electronic brain of your ICP RGS210LRCA0AAAA system. It manages the ignition sequence, blower and inducer timing, safety lockouts, and communication between the thermostat and the unit's components. The kit includes the board and necessary mounting hardware for a complete replacement. Control boards fail from power surges, heat stress, corroded relays, or cracked solder joints — symptoms include a dead unit, blinking diagnostic LED fault codes, blowers or igniters that won't sequence, or erratic operation. Replacing a failed board with a genuine OEM kit restores full diagnostic and safety functionality.

Specifications

Spec Value
Part Number 1183618
Type Control Board Kit
Brand ICP
Function Ignition / Timing / Safety Control
Includes Board + Mounting Hardware

Compatibility

Direct OEM replacement kit for the ICP / Tempstar / Heil RGS210LRCA0AAAA and compatible RGS210 series units. Match the board part number and connector layout to your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the control compartment / service panel.
  3. Document — Photograph every connector and wire harness position before disconnecting.
  4. Remove — Unplug all harnesses, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board with the included hardware and reconnect each harness per your photo.
  6. Test — Restore power, clear any fault codes, and verify a full heating and cooling sequence.

Signs You Need a Replacement

  • Unit completely dead with no response
  • Flashing diagnostic LED fault codes
  • Blower, inducer, or igniter fails to sequence
  • Visible burn marks, corrosion, or scorched relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS210LRCA0AAAA — OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS210LRCA0AAAA — OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS210LRCA0AAAA — OEM Replacement | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online