Overview

This genuine OEM control board kit (part 1183618) is the integrated furnace control (IFC) for the ICP / Heil / Tempstar RGS210HSCA0AAAA. The control board is the brain of the furnace: it sequences the ignition cycle, runs the inducer and circulating blower, monitors safety devices such as the limit and pressure switches and flame sensor, and flashes diagnostic fault codes via its onboard LED. Supplied as a kit, it includes the board and the hardware needed for a complete replacement. A failed board commonly results in a furnace that is completely dead, won't start the inducer or blower, runs the blower continuously, or repeatedly locks out despite good supporting components.

Specifications

Spec Value
Part Number 1183618 (Kit, Control Board)
Type Integrated Furnace Control Board
Function Ignition, Blower & Safety Control
Diagnostics Onboard LED Fault Codes
Brand ICP (Heil / Tempstar)
Fitment OEM

Compatibility

Designed for the ICP-built RGS210HSCA0AAAA and shared across compatible Heil, Tempstar, Comfortmaker, and Arcoaire furnaces. Always match OEM number 1183618 and the board's connector layout to your existing control before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment panel.
  3. Document — Photograph every wire harness and plug location on the old board.
  4. Remove — Unplug each connector, release the board from its standoffs/screws, and lift it out.
  5. Install — Mount the new board, transfer connectors exactly per your photo, and confirm each plug is fully seated.
  6. Test — Restore power, run a full heat cycle, and confirm proper ignition, blower operation, and no fault codes.

Signs You Need a Replacement

  • Furnace is completely unresponsive with no LED activity
  • Inducer or blower won't start despite a valid call
  • Blower runs constantly or behaves erratically
  • Persistent lockouts or error codes with good sensors and switches

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS210HSCA0AAAA — OEM Furnace Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS210HSCA0AAAA — OEM Furnace Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS210HSCA0AAAA — OEM Furnace Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.