This genuine OEM control board kit, part number 1183618, is the integrated furnace control (IFC) for the ICP Tempstar Heil RGS210HRCA0AAAA. The board is the brain of the furnace: it sequences the ignition cycle, energizes the inducer and igniter, opens the gas valve, monitors flame and safety limits, and times the blower on and off. It also runs the self-diagnostic LED fault codes technicians use to troubleshoot. Control boards fail from power surges, cracked solder joints, burned relays, or corroded connectors — symptoms that range from a completely dead furnace to erratic blower behavior, ignition lockouts, or missing diagnostic codes. The kit ships with the correct OEM board so the ignition timing, relay ratings, and safety logic exactly match the original equipment.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Function Ignition, Blower & Safety Control
Control Voltage 24V
Brand ICP / Tempstar / Heil
Fitment OEM

Compatibility

Built for ICP-family gas furnaces (Tempstar, Heil, Comfortmaker), including model RGS210HRCA0AAAA and related RGS210 series units. Compare the board layout, connector positions, and part number against your original before installing.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the blower/control compartment panel.
  3. Document — Photograph every harness and connector on the old board before unplugging anything.
  4. Remove — Disconnect the harnesses, release the mounting standoffs or screws, and lift out the failed board.
  5. Install — Mount the new board, then reconnect each harness in the identical position per your photos.
  6. Test — Restore power, run a full heat cycle, and confirm proper ignition, blower timing, and clean diagnostic codes.

Signs You Need a Replacement

  • Furnace is completely unresponsive with no diagnostic LED.
  • No ignition sequence despite a valid heat call.
  • Erratic or stuck blower operation.
  • Burned relays, scorch marks, or corroded connectors on the old board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS210HRCA0AAAA — OEM Furnace Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS210HRCA0AAAA — OEM Furnace Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS210HRCA0AAAA — OEM Furnace Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.