Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGS210HFAA0AAAA — Furnace Ignition Control | Ships Today
ICP

ICP Control Board Kit for RGS210HFAA0AAAA — Furnace Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part 1183618) is the brain of ICP / Tempstar / Heil model RGS210HFAA0AAAA. The integrated furnace control board sequences the entire heating cycle — it reads the thermostat call, runs the inducer and pressure-switch safety checks, energizes ignition, opens the gas valve, monitors flame, and times the blower on/off. It also manages the 24V control circuitry and onboard diagnostics. When the board fails, you'll typically see no response to a heat call, blower or inducer running continuously, repeated lockouts, or a diagnostic LED flashing an error code. Shipped as a kit with the hardware needed to drop it in.

Specifications

Spec Value
Part Number 1183618 (Kit)
Type Integrated Furnace Control Board
Brand ICP / Tempstar / Heil
Control Voltage 24V
Function Ignition, Blower & Safety Sequencing
Fitment OEM Replacement Kit

Compatibility

Built for ICP-family RGS-series gas furnaces, including model RGS210HFAA0AAAA, and supersedes earlier boards on related Tempstar, Heil, and Comfortmaker furnaces per the kit instructions. Match your current board's connector layout and confirm the kit number before installing.

Installation Guide

  1. Safety First — Disconnect power and shut off gas, then verify zero voltage with a multimeter before opening the control box.
  2. Access — Remove the furnace service panel to reach the control board.
  3. Document — Photograph every harness plug and terminal connection before disconnecting.
  4. Remove — Unplug the connectors, release the board from its standoffs, and lift it out.
  5. Install — Mount the new board, transfer any jumpers/links, and reconnect each harness per your photo.
  6. Test — Restore gas and power, run a full heat cycle, and confirm proper ignition, flame proof, and blower timing with no fault codes.

Signs You Need a Replacement

  • No response from the furnace on a thermostat heat call
  • Blower or inducer motor runs constantly or won't start
  • Repeated ignition lockouts not traced to igniter, valve, or sensor
  • Diagnostic LED flashing a hard-fault or control error code

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS210HFAA0AAAA — Furnace Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS210HFAA0AAAA — Furnace Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS210HFAA0AAAA — Furnace Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online