Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGS210HEAA0AAAA — OEM Furnace Control 1183618 | Ships Today
ICP

ICP Control Board Kit for RGS210HEAA0AAAA — OEM Furnace Control 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM control board kit, part number 1183618, for ICP, Heil, and Tempstar package units such as the RGS210HEAA0AAAA. The integrated furnace control board is the brain of the unit: it sequences the entire heat cycle, runs the igniter, opens the gas valve, monitors safeties (limits, pressure/rollout switches, flame sense), times the inducer and blower, and stores fault codes on its diagnostic LED. The kit ships with the mounting hardware and connectors needed for a clean swap. Control boards fail from power surges, corrosion, cracked solder joints, and failed relays — symptoms include a completely dead unit, no ignition sequence, the blower running constantly or not at all, or a fault LED flashing a specific error pattern. Replacing the board restores full automatic operation and clears board-level lockouts.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Heil / Tempstar
Control Voltage 24 VAC
Diagnostics On-board fault LED
Fit OEM Replacement Kit

Compatibility

Fits the ICP/Tempstar/Heil RGS210HEAA0AAAA gas package unit and related RGS210-series models that use the 1183618 control board kit. Match the part number to your existing board before ordering, as control boards are model-specific.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the control-compartment panel to expose the board.
  3. Document — Photograph every harness and plug location; note any DIP switch or jumper settings.
  4. Remove — Unplug each connector, release the board standoffs, and lift out the old board.
  5. Install — Mount the new board on the supplied standoffs, transfer all connectors to the matching headers per your photo, and replicate the DIP/jumper settings.
  6. Test — Restore power and run a full heat and blower cycle; confirm a steady (normal) LED with no fault codes.

Signs You Need a Replacement

  • Unit completely dead with no response to a thermostat call.
  • No ignition sequence — inducer or igniter never energizes.
  • Blower runs constantly or won't run at all.
  • Diagnostic LED flashing a hard-fault or internal-error code.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS210HEAA0AAAA — OEM Furnace Control 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS210HEAA0AAAA — OEM Furnace Control 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS210HEAA0AAAA — OEM Furnace Control 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online