Overview

This is the genuine OEM control board kit (part number 1183618) for the ICP Tempstar Heil RGS150SFCA0AAAA gas furnace. The integrated furnace control board is the brain of the system — it manages the ignition sequence, monitors safety circuits (limit switches, pressure switches, flame sensing), times the inducer and blower, and coordinates every call for heat from the thermostat. When the board fails, symptoms range from no response at all to erratic cycling, blower or inducer that won't start or won't stop, and ignition lockouts. Supplied as a complete kit, this OEM board restores correct, code-compliant operation and protects the rest of your furnace components.

Specifications

Spec Value
Part Number 1183618
Description Kit, Control Board
Type Integrated Furnace Control (IFC) Board
Brand ICP / Tempstar / Heil
Fits Model RGS150SFCA0AAAA
Application Gas Furnace Control
Fit Direct OEM Replacement

Compatibility

Direct-fit replacement for the ICP Tempstar Heil RGS150SFCA0AAAA. This control board kit fits related ICP-family furnaces (Tempstar, Heil, Comfortmaker, Arcoaire, KeepRite) built on the same control platform. Because control boards are revision-specific, always confirm part number 1183618 against the label on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect electrical power to the furnace and verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment service panel.
  3. Document — Photograph every wire harness and terminal on the existing board before disconnecting — this is critical for correct reassembly.
  4. Remove — Unplug all connectors, then unfasten and remove the old control board from its mounting standoffs.
  5. Install — Mount the new board, then reconnect each harness to the matching terminal per your photos. Set any DIP switches/jumpers to match the original.
  6. Test — Restore power and run a full heat cycle, confirming proper inducer, igniter, gas valve, and blower sequencing.

Signs You Need a Replacement

  • Furnace completely unresponsive to thermostat calls
  • Erratic short-cycling or blower/inducer that won't start or stop
  • Repeated ignition lockouts with no component fault found
  • Visible burn marks, scorched traces, or a blown fuse on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS150SFCA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS150SFCA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS150SFCA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online