Overview

This is the OEM integrated furnace control board kit (part number 1183618) for the ICP / Tempstar / Heil RGS121LECA0AAA gas furnace. The control board is the brain of your furnace — it manages the ignition sequence, monitors safety limit and flame signals, sequences the inducer motor, gas valve, and blower, and reports fault codes through its diagnostic LED. When the board fails, your furnace may stop responding to thermostat calls, lock out on ignition, short-cycle, or run the blower continuously. This factory kit includes the replacement board so you can restore full, reliable operation rather than chasing intermittent symptoms.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil / Comfortmaker)
Control Voltage 24V
Fits Model RGS121LECA0AAA
Fitment OEM Direct Replacement

Compatibility

Engineered as a direct-fit replacement for the ICP-family RGS121LECA0AAA gas furnace and is sold under the Tempstar, Heil, and Comfortmaker badges that share this chassis. Always confirm your existing board part number (1183618) before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower/control compartment door.
  3. Document — Photograph every wire and connector location on the old board before disconnecting anything.
  4. Remove — Unplug the low-voltage and line-voltage harnesses, release the board mounting standoffs/screws, and lift the old board out.
  5. Install — Seat the new board on the standoffs, reconnect each harness exactly per your photos, and confirm no pins are bent.
  6. Test — Restore power, initiate a heat call, and watch the diagnostic LED for a steady/normal code through a full ignition cycle.

Signs You Need a Replacement

  • Furnace does not respond to thermostat heat calls.
  • Inducer or blower fails to start, or blower runs nonstop.
  • Repeated ignition lockouts or flashing fault codes on the board LED.
  • Visible burn marks, corrosion, or a tripped onboard fuse.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS121LECA0AAA – Furnace Control Module | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS121LECA0AAA – Furnace Control Module | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS121LECA0AAA – Furnace Control Module | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.