Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGS121HFCA0AAA Gas Furnace — Integrated Furnace Control | Ships Today
ICP

ICP Control Board Kit for RGS121HFCA0AAA Gas Furnace — Integrated Furnace Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM Integrated Furnace Control (IFC) board kit, part number 1183618, is the central brain of your ICP Tempstar/Heil RGS121HFCA0AAA gas furnace. It manages the entire heating sequence — igniter timing, gas valve operation, inducer and blower motor control, flame sensing, and safety lockouts. The board interprets thermostat calls and orchestrates each component in the correct order while continuously monitoring limit and pressure switches. When this board fails, the furnace may fail to ignite, short-cycle, lock out on flashing diagnostic LEDs, or run the blower continuously. This direct-replacement kit restores reliable, code-compliant operation.

Specifications

Spec Value
Part Number 1183618 (KIT CONTROL BOARD)
Type Integrated Furnace Control Board
Brand ICP / Tempstar / Heil
Control Voltage 24V
Fits Model RGS121HFCA0AAA
Fit OEM Direct Replacement

Compatibility

Engineered specifically for the ICP/Tempstar/Heil RGS121HFCA0AAA gas furnace and closely related RGS121 series units that call out part 1183618. Always confirm the part number printed on your existing board before ordering to guarantee an exact fit.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, shut off the gas, and verify zero voltage with a multimeter.
  2. Access — Remove the lower blower-compartment service panel to expose the control board.
  3. Document — Photograph every wire harness and connector before disconnecting anything.
  4. Remove — Unplug all low- and line-voltage connectors, release the board's mounting tabs/screws, and lift out the old board.
  5. Install — Mount the new board, then reconnect each harness exactly as photographed.
  6. Test — Restore gas and power, run a full heat cycle, and confirm proper igniter, gas valve, and blower sequencing with no diagnostic faults.

Signs You Need a Replacement

  • Furnace will not start or igniter never energizes on a heat call
  • Repeated lockouts or flashing error codes on the board's diagnostic LED
  • Blower runs constantly or fails to start
  • Visible burn marks, corrosion, or cracked solder joints on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS121HFCA0AAA Gas Furnace — Integrated Furnace Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS121HFCA0AAA Gas Furnace — Integrated Furnace Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS121HFCA0AAA Gas Furnace — Integrated Furnace Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.