Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGS102STCA0AAA — OEM Furnace Ignition Board 1183618 | Ships Today
ICP

ICP Control Board Kit for RGS102STCA0AAA — OEM Furnace Ignition Board 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part number 1183618) is the integrated furnace control (IFC) module for the ICP / Tempstar / Heil RGS102STCA0AAA gas furnace. The control board is the brain of the furnace — it sequences the ignition cycle, monitors safety limits and flame signal, controls the inducer and blower motors, and manages the 24V control circuit. When this board fails, the furnace may fail to ignite, short-cycle, lock out, run the blower continuously, or stop responding to the thermostat entirely. Supplied as a complete kit with the correct mounting and connector hardware for a direct OEM replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Control Voltage 24V
Fitment OEM Direct Replacement
Model RGS102STCA0AAA

Compatibility

Engineered as the factory control board for the ICP / Tempstar / Heil RGS102STCA0AAA gas furnace and shared chassis variants across the ICP family (Comfortmaker, Arcoaire, KeepRite). Always confirm the part number printed on your existing board matches 1183618 before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage at the board with a multimeter before touching any connections.
  2. Access — Remove the furnace blower-compartment service panel to expose the control board.
  3. Document — Photograph every wire harness and terminal connection on the existing board before disconnecting anything.
  4. Remove — Unplug the molex/spade connectors, remove the board mounting screws or standoffs, and lift out the failed board.
  5. Install — Mount the new board, transfer connectors one at a time to match your photos, and seat each harness fully.
  6. Test — Restore power, call for heat, and verify the full ignition sequence: inducer, igniter, gas valve, flame proof, and blower.

Signs You Need a Replacement

  • Furnace will not start or has no response from the thermostat
  • Blower runs continuously or fails to start during a heat call
  • Repeated lockouts or fault/diagnostic LED flash codes
  • Visible burnt traces, scorched relays, or a melted connector on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102STCA0AAA — OEM Furnace Ignition Board 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102STCA0AAA — OEM Furnace Ignition Board 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102STCA0AAA — OEM Furnace Ignition Board 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online