Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGS102LTBB0AAA — OEM Furnace Ignition Board 1183618 | Ships Today
ICP

ICP Control Board Kit for RGS102LTBB0AAA — OEM Furnace Ignition Board 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM control board kit (part number 1183618) for the ICP Tempstar Heil RGS102LTBB0AAA gas furnace. The integrated furnace control board is the brain of the heating system: it manages the ignition sequence, monitors the flame sensor and pressure switch safeties, sequences the inducer and blower motors, and controls the 24V gas valve. When this board fails, the furnace will not start, will lock out after a few ignition attempts, or will short-cycle. Common failure symptoms include a blank or flashing diagnostic LED, no response to a thermostat call for heat, the inducer running but no ignition, or the blower running continuously. This kit replaces the original board and restores full control of the ignition and blower sequencing.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Control Voltage 24V
Fits Model RGS102LTBB0AAA
Fitment OEM Direct Replacement

Compatibility

This control board kit is engineered as a direct OEM replacement for the ICP Tempstar Heil RGS102LTBB0AAA gas furnace. ICP manufactures equipment under multiple labels (Tempstar, Heil, Comfortmaker, Arcoaire), so this board may also service equivalently configured models in those families. Always confirm the original board part number (1183618) or cross-reference printed on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage at the board with a multimeter before touching any wiring.
  2. Access — Remove the furnace blower-compartment service panel to expose the control board.
  3. Document — Take a clear photo of every wire and connector position on the existing board before disconnecting anything.
  4. Remove — Unplug the wiring harnesses and molex connectors, remove the mounting screws or standoffs, and lift out the failed board.
  5. Install — Mount the new 1183618 board, transfer each connector to the identical terminal per your photo, and confirm the harness clips are fully seated.
  6. Test — Restore power, initiate a call for heat, and watch the diagnostic LED to confirm a normal ignition and blower sequence with no fault codes.

Signs You Need a Replacement

  • Furnace does not respond to a thermostat call for heat.
  • Inducer runs but the igniter or gas valve never energizes.
  • System locks out after repeated failed ignition attempts.
  • Diagnostic LED is dead, or flashes a hard-lockout / board fault code.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102LTBB0AAA — OEM Furnace Ignition Board 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102LTBB0AAA — OEM Furnace Ignition Board 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102LTBB0AAA — OEM Furnace Ignition Board 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online