Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGS102LSCA0AAA — Furnace Integrated Ignition Control | Ships Today
ICP

ICP Control Board Kit for RGS102LSCA0AAA — Furnace Integrated Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part #1183618) is the integrated furnace ignition control module for the ICP Tempstar Heil RGS102LSCA0AAA gas furnace. The control board is the brain of the furnace: it sequences the ignition cycle, monitors the flame sensor and limit switches, controls the inducer and blower motors, and manages safety lockouts. Operating on 24V control logic, it coordinates every step from a thermostat call for heat through ignition, flame proving, and blower-off delay. When this board fails, the furnace typically will not start, short-cycles, throws repeating fault codes on the diagnostic LED, or runs the blower continuously. Because it is a complete kit, it includes the mounting and connection hardware needed for a clean replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Control Voltage 24V
Function Ignition sequencing, flame monitoring, blower/inducer control
Fit OEM Replacement

Compatibility

Engineered as the direct OEM replacement for the ICP Tempstar Heil RGS102LSCA0AAA gas furnace. ICP-family equipment (Heil, Tempstar, Comfortmaker, and related Carrier-group brands) frequently shares control board platforms, but always confirm the part number on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower/service panel to expose the control board.
  3. Document — Photograph every wire and connector position before disconnecting anything.
  4. Remove — Unplug the low-voltage and line-voltage harnesses, release the board standoffs/screws, and lift out the old board.
  5. Install — Mount the new board on the standoffs and reconnect each harness exactly per your photos.
  6. Test — Restore power, initiate a call for heat, and confirm a full ignition cycle with no fault codes.

Signs You Need a Replacement

  • Furnace fails to ignite or does not respond to a thermostat call.
  • Repeating or flashing diagnostic fault codes on the control LED.
  • Blower runs constantly or never starts during a heat cycle.
  • Visible burns, corrosion, or cracked solder joints on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102LSCA0AAA — Furnace Integrated Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102LSCA0AAA — Furnace Integrated Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102LSCA0AAA — Furnace Integrated Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.