Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGS101HSCB0AAA Gas Furnace — Integrated Furnace Control | Ships Today
ICP

ICP Control Board Kit for RGS101HSCB0AAA Gas Furnace — Integrated Furnace Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM integrated furnace control board kit (part number 1183618) for the ICP / Tempstar / Heil RGS101HSCB0AAA gas furnace. The control board is the brain of the furnace — it manages the ignition sequence, monitors the flame sensor and pressure switch, sequences the inducer and blower motors, and enforces safety lockouts. When it fails, the furnace typically will not start, locks out after a few ignition attempts, runs the blower continuously, or throws diagnostic fault codes via the on-board LED. This kit ships complete and ready to drop in.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Fits Model RGS101HSCB0AAA
Function Ignition, blower & inducer sequencing, safety lockout
Fit OEM Replacement

Compatibility

Engineered as the direct OEM replacement for the ICP / Tempstar / Heil RGS101HSCB0AAA gas furnace. Always confirm the part number printed on your existing board matches 1183618 before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, and verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the furnace blower-compartment service panel to expose the control board.
  3. Document — Photograph every wire and connector position before disconnecting anything.
  4. Remove — Unplug the low-voltage and line-voltage connectors, release the mounting standoffs/screws, and lift out the failed board.
  5. Install — Seat the new board on the standoffs, secure it, and reconnect every harness exactly per your photos.
  6. Test — Restore power and run a full heat cycle; confirm ignition, flame proving, and blower handoff with no fault codes.

Signs You Need a Replacement

  • Furnace will not ignite or locks out after repeated ignition attempts.
  • Blower runs constantly or never engages.
  • Error/diagnostic LED flashing fault codes.
  • No response to thermostat call for heat despite good 24V signal.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS101HSCB0AAA Gas Furnace — Integrated Furnace Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS101HSCB0AAA Gas Furnace — Integrated Furnace Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS101HSCB0AAA Gas Furnace — Integrated Furnace Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online