Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGS091STCB0AAA — OEM 1183618 Integrated Furnace Control | Ships Today
ICP

ICP Control Board Kit for RGS091STCB0AAA — OEM 1183618 Integrated Furnace Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM integrated furnace control board kit (part number 1183618) for the ICP Tempstar Heil RGS091STCB0AAA gas furnace. The control board is the brain of the furnace — it manages the ignition sequence, monitors safety limits and flame sensing, sequences the inducer and blower motors, and reports fault codes through its onboard diagnostic LED. When this board fails the furnace will typically lock out, fail to ignite, short-cycle, or run the blower continuously. Because it ships as a complete kit, it includes the mounting hardware and wiring connectors needed for a clean, direct replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Control Voltage 24V
Fit OEM Direct Replacement
Diagnostics Onboard LED fault codes

Compatibility

Engineered as a direct-fit replacement for the ICP Tempstar Heil RGS091STCB0AAA furnace. ICP-family equipment (Heil, Tempstar, Comfortmaker) frequently shares control platforms, so this board also services closely related models — confirm your existing board part number against 1183618 before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage at the board with a multimeter.
  2. Access — Remove the furnace blower-compartment service panel.
  3. Document — Photograph every wire and connector on the existing board before disconnecting anything.
  4. Remove — Label and unplug all connectors, remove the board mounting screws, and lift out the old control.
  5. Install — Mount the new board to the same standoffs and reconnect each connector exactly per your photo.
  6. Test — Restore power and run a full heat cycle; confirm the diagnostic LED shows normal operation with no fault codes.

Signs You Need a Replacement

  • Furnace will not ignite or repeatedly locks out
  • Blower runs continuously or never starts
  • Rapid short-cycling on the heat call
  • Diagnostic LED flashing an error code or a dark/dead board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS091STCB0AAA — OEM 1183618 Integrated Furnace Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS091STCB0AAA — OEM 1183618 Integrated Furnace Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS091STCB0AAA — OEM 1183618 Integrated Furnace Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera