Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGS091HTCB0AAA — OEM Furnace Ignition Control | Ships Today
ICP

ICP Control Board Kit for RGS091HTCB0AAA — OEM Furnace Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine ICP control board kit (part 1183618) for the RGS091HTCB0AAA gas furnace. The integrated furnace control board is the brain of the system: it sequences ignition, manages the inducer and blower motors, monitors safety devices such as the limit and pressure switches, controls the gas valve and igniter timing, and flashes diagnostic fault codes when something goes wrong. When the board fails, the symptoms can mimic almost any other part — no ignition, short cycling, blower that won't shut off, or a completely dead furnace. Voltage surges, overheating, corroded relays, and aged solder joints are common causes of board failure. This OEM kit is a direct, factory-matched replacement that restores correct ignition sequencing and full diagnostic capability.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Heil / Tempstar / Comfortmaker
Function Ignition sequencing, blower/inducer control, safety monitoring, diagnostics
Fit Genuine OEM
Application Gas furnace primary control

Compatibility

Built for the ICP/Tempstar/Heil RGS091HTCB0AAA gas furnace and ICP-family units that use this integrated control. Confirm the board part number, connector layout, and mounting footprint against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control-compartment service panel.
  3. Document — Photograph every plug, harness, and terminal on the old board before disconnecting anything.
  4. Remove — Unplug all connectors, release the standoffs or screws, and lift out the failed board.
  5. Install — Mount the new board on its standoffs and reconnect every harness to the matching terminal per your photos.
  6. Test — Restore power, run a full heat cycle, and confirm proper ignition sequencing with no fault codes flashing.

Signs You Need a Replacement

  • Furnace completely dead with no response to a heat call
  • Blower or inducer runs continuously or won't start
  • Repeated short cycling or failed ignition sequences
  • Diagnostic LED flashing a control-fault or hardware error code

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS091HTCB0AAA — OEM Furnace Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS091HTCB0AAA — OEM Furnace Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS091HTCB0AAA — OEM Furnace Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart