This is the OEM control board kit, part number 1183618, for the ICP / Tempstar / Heil RGS090SFCA0AAA gas furnace. The integrated furnace control board is the brain of the system — it manages the entire ignition sequence, monitors safety limits and flame sensing, sequences the inducer and blower motors, and times the heating and cooling cycles. Supplied as a complete kit with mounting and connection hardware for a direct replacement. When the control board fails, the furnace can lose heat entirely, short-cycle, run the blower continuously, or throw fault/flash codes at the diagnostic LED. Because the board ties every component together, replacing a failed one restores correct, safe sequencing across the whole furnace.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Function Ignition, blower/inducer timing, safety & flame monitoring
Includes Control board + mounting/connection kit
Fitment OEM

Compatibility

Engineered for the ICP RGS090SFCA0AAA furnace and related ICP-family units (Tempstar, Heil, Comfortmaker) that use this integrated control. Match the board part number and connector layout to your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the furnace control/blower compartment panel to expose the board.
  3. Document — Photograph every connector and wire harness on the board before disconnecting — this is the most important step.
  4. Remove — Unplug each harness, remove the board mounting screws/standoffs, and lift out the old board.
  5. Install — Mount the new board, transfer any jumpers/links, and reconnect each harness to the matching terminal per your photos.
  6. Test — Restore power, call for heat and cool, and confirm a full normal sequence with no fault flash codes at the diagnostic LED.

Signs You Need a Replacement

  • No heat with no ignition sequence starting
  • Blower runs constantly or won't start
  • Repeated fault/flash codes at the board LED
  • Visible burnt traces, scorching, or corroded relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS090SFCA0AAA — OEM Furnace Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS090SFCA0AAA — OEM Furnace Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS090SFCA0AAA — OEM Furnace Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online