Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board for WTA3242000RKA1 — X-13 ECM Motor Module | Ships Today
ICP

ICP Control Board for WTA3242000RKA1 — X-13 ECM Motor Module | Ships Today

SKU: WTA3242000RKA1 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM X-13 control board (part 1173692) is the motor control module that drives the X-13 / constant-torque ECM blower motor in your ICP Tempstar Heil WTA3242000RKA1 air handler. The board receives 24V thermostat signals and translates them into the programmed torque steps the ECM motor uses to deliver the correct airflow for cooling, heating, and continuous-fan modes. When this module fails, the blower may not start, may run at the wrong speed, may cycle erratically, or may throw a motor-communication fault. Because the X-13 motor and its control are a matched pair, replacing a failed board with the exact OEM module is the most reliable way to restore proper airflow and protect the motor.

Specifications

Spec Value
Part Number 1173692
Type X-13 ECM Motor Control Board
Brand ICP (Tempstar / Heil)
Control Voltage 24V
Fits Model WTA3242000RKA1
Fitment OEM Exact Replacement

Compatibility

Designed as a direct factory replacement for the X-13 motor module in the ICP Tempstar Heil WTA3242000RKA1 air handler and closely related ICP-family air handlers using the same X-13 ECM blower platform. Always confirm the printed part number on your existing board matches 1173692 before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage at the board with a multimeter.
  2. Access — Remove the air handler blower-compartment service panel.
  3. Document — Photograph every wire and connector position before disconnecting.
  4. Remove — Unplug the motor harness and 24V connections, release the board standoffs or screws, and lift the old module out.
  5. Install — Seat the new board on the standoffs and reconnect each harness exactly as photographed.
  6. Test — Restore power and confirm the blower starts and ramps to correct speed in cool, heat, and fan modes.

Signs You Need a Replacement

  • Blower motor will not run or only hums.
  • Airflow stuck at one speed or wrong speed for the mode.
  • Intermittent blower operation or nuisance shutdowns.
  • Motor or control fault code at the board or thermostat.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WTA3242000RKA1 — X-13 ECM Motor Module | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WTA3242000RKA1 — X-13 ECM Motor Module | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WTA3242000RKA1 — X-13 ECM Motor Module | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.