Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board for WPH4484000RKA1 — Defrost Circuit Board | Ships Today
ICP

ICP Control Board for WPH4484000RKA1 — Defrost Circuit Board | Ships Today

SKU: WPH4484000RKA1 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM circuit board (part number 1178001) is the factory replacement control board for the ICP / Tempstar / Heil WPH4484000RKA1 heat pump. On a heat-pump condensing unit this board manages the defrost cycle, sequences the compressor and reversing valve, and coordinates the 24V control signals between the thermostat and the outdoor components. It monitors the defrost timer and coil temperature, switching the unit into and out of defrost so the outdoor coil sheds frost in heating mode. A failed control board causes erratic operation — no compressor, a unit stuck in defrost, ice buildup on the outdoor coil, or a complete no-heat condition. Installing a new board restores correct cycle timing and reliable heating and cooling.

Specifications

Spec Value
Part Number 1178001
Type Control / Defrost Circuit Board
Brand ICP / Tempstar / Heil
Control Voltage 24V
Function Defrost timing, compressor & reversing valve sequencing
Fitment OEM

Compatibility

Built as the direct replacement for the ICP WPH4484000RKA1 heat pump condensing unit. Because ICP manufactures for multiple brands, this board also services equivalent Tempstar, Heil, Comfortmaker, and Arcoaire outdoor units originally equipped with part 1178001. Match the board's part number and connector layout to your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter before handling the board.
  2. Access — Remove the service panel to expose the control compartment.
  3. Document — Photograph every plug and wire on the old board; note the defrost timer setting (jumper or dip switch).
  4. Remove — Unplug each connector, release the board standoffs or screws, and lift the board out.
  5. Install — Seat the new board, set the defrost timing to match the original, and reconnect every plug per your photo.
  6. Test — Restore power, run a heating and cooling call, and confirm the compressor, reversing valve, and defrost cycle operate correctly.

Signs You Need a Replacement

  • Heat pump won't start in heating or cooling despite a good thermostat signal.
  • Outdoor coil ices over because the unit never enters defrost.
  • Unit gets stuck in defrost or short-cycles the compressor.
  • Visible scorch marks, burnt relays, or a cracked board.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WPH4484000RKA1 — Defrost Circuit Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WPH4484000RKA1 — Defrost Circuit Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WPH4484000RKA1 — Defrost Circuit Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart