Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board for WPG3424060LKC1 — OEM Ignition Control Module | Ships Today
ICP

ICP Control Board for WPG3424060LKC1 — OEM Ignition Control Module | Ships Today

SKU: 1178358 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This ICP control board / ignition control module (OEM circuit board #1178358 and ignition control module #1177661) is the brain of the WPG3424060LKC1 package unit's heating sequence. It manages the ignition sequence — energizing the inducer, proving the pressure switch, powering the hot surface igniter, opening the gas valve, sensing flame, and running the blower on the correct timing. It also enforces safety lockouts on flame failure or pressure faults. When this board fails you'll see no ignition, erratic blower behavior, repeated lockouts, or a unit that ignores the thermostat entirely.

Specifications

Spec Value
Part Numbers 1178358 (Circuit Board), 1177661 (Ignition Control Module)
Type Integrated Ignition Control Board
Brand ICP / Tempstar / Heil
Control Voltage 24V
Function Ignition sequencing, flame sensing, blower timing, safety lockout
Fitment WPG3424060LKC1

Compatibility

Built for the ICP / Tempstar / Heil WPG3424060LKC1 package gas/electric unit. Match OEM numbers 1178358 / 1177661 to your failed board; control boards are sequence- and pinout-specific and a mismatched board will not stage ignition correctly.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and shut off gas. Verify zero voltage with a multimeter.
  2. Access — Remove the control compartment service panel.
  3. Document — Photograph every wire harness and terminal location on the board before disconnecting — this is critical for a multi-connection board.
  4. Remove — Unplug all connectors, remove the mounting screws/standoffs, and lift out the old board.
  5. Install — Mount the new board, then reconnect each harness exactly per your photos. Confirm no pins are bent or mis-seated.
  6. Test — Restore gas and power, run a full heat cycle, and verify proper ignition sequence and blower timing.

Signs You Need a Replacement

  • No response to thermostat heat calls despite control power
  • Repeated ignition lockouts with no other failed component found
  • Blower runs continuously or won't start on the correct delay
  • Visible scorching, burnt traces, or a failed onboard fuse/relay

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WPG3424060LKC1 — OEM Ignition Control Module | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WPG3424060LKC1 — OEM Ignition Control Module | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WPG3424060LKC1 — OEM Ignition Control Module | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online