Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board for WPA4424000RKB1 — OEM Circuit Board | Ships Today
ICP

ICP Control Board for WPA4424000RKB1 — OEM Circuit Board | Ships Today

SKU: 1178001 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM control circuit board (part number 1178001) for the ICP/Tempstar/Heil model WPA4424000RKB1. The control board is the brain of the outdoor unit — it takes the 24V signal from the thermostat, manages the contactor and fan timing, runs anti-short-cycle and time-delay logic, and on heat-pump units coordinates defrost and reversing-valve operation. Because it is packed with relays, capacitors, and solid-state components, it is vulnerable to power surges, lightning, voltage spikes, and simple age-related failure. A bad board produces frustrating, intermittent symptoms: the unit ignores the thermostat, short-cycles, will not stage properly, or behaves erratically with no obvious mechanical fault. Replacing the board with the exact OEM part restores correct, reliable sequencing.

Specifications

Spec Value
Part Number 1178001
Type Control / Circuit Board
Brand ICP / Tempstar / Heil
Control Voltage 24V
Fits Model WPA4424000RKB1

Compatibility

Designed for the ICP, Tempstar, Heil, and Comfortmaker unit WPA4424000RKB1, and a direct OEM replacement for part 1178001. Match the board's part number and connector layout to your existing board before installing, as control boards are model-specific.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical-compartment service panel.
  3. Document — Photograph every plug, harness, and terminal on the board before disconnecting.
  4. Remove — Unplug the connectors, release the standoffs or screws, and lift out the failed board.
  5. Install — Mount the new board on the standoffs and reconnect each harness to its matching terminal per your photo.
  6. Test — Restore power, call for cooling/heating, and confirm correct contactor, fan, and (if applicable) defrost sequencing.

Signs You Need a Replacement

  • Unit does not respond to the thermostat despite good 24V power.
  • Intermittent or erratic operation with no mechanical cause.
  • Short-cycling or failure to honor time-delay logic.
  • Visible burn marks, scorched traces, or a blown relay on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WPA4424000RKB1 — OEM Circuit Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WPA4424000RKB1 — OEM Circuit Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WPA4424000RKB1 — OEM Circuit Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online