ICP Control Board for WPA4424000RKA1 — OEM Circuit Board | Ships Today
ICP

ICP Control Board for WPA4424000RKA1 — OEM Circuit Board | Ships Today

SKU: 1178001 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control circuit board (part number 1178001) is the electronic brain of your ICP WPA4424000RKA1 system. It receives the thermostat signal, manages compressor and fan timing, enforces safety lockouts and anti-short-cycle delays, and sequences the unit's components in the correct order. When a control board fails, the symptoms can be intermittent and frustrating: the system ignores the thermostat, short cycles, fails to start, or runs without responding to commands. Power surges, lightning, moisture intrusion, and burnt relays are common causes of board failure. Installing the exact OEM board ensures correct timing logic and full compatibility with the unit's safeties.

Specifications

Spec Value
Part Number 1178001
Type Control Circuit Board
Brand ICP / Heil / Tempstar
Function Timing, Sequencing & Safety Control
Fit OEM Direct Replacement

Compatibility

Direct-fit OEM replacement for the ICP/Heil/Tempstar/Comfortmaker WPA4424000RKA1 and units using the same control board. Match the part number and connector layout to your original board before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter before handling the board.
  2. Access — Remove the service panel to reach the control board.
  3. Document — Photograph every connector, plug, and wire position on the board.
  4. Remove — Unplug all connectors and remove the mounting screws or standoffs holding the board.
  5. Install — Seat the new board on the standoffs and reconnect every plug exactly per your photo.
  6. Test — Restore power, call for operation, and confirm correct sequencing and no fault codes.

Signs You Need a Replacement

  • System does not respond to the thermostat or runs erratically.
  • Persistent short cycling or failure to start.
  • Visible burn marks, scorched relays, or a burnt smell on the board.
  • Error/fault codes pointing to a control failure.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WPA4424000RKA1 — OEM Circuit Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WPA4424000RKA1 — OEM Circuit Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WPA4424000RKA1 — OEM Circuit Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.