This is the OEM control circuit board (Part #1178001) for the ICP WPA4364000RKB1 unit. The control board is the brain of the system — it manages startup sequencing, relay timing, safety lockouts, and (on heat pump models) defrost cycles based on input from the thermostat and sensors. When a control board fails, you may see a unit that won't respond to thermostat calls, erratic cycling, components that energize at the wrong time, or diagnostic LED fault codes. Boards commonly fail from power surges, lightning, moisture, or burned relays and traces. Replacing the board restores correct, safe sequencing of the entire unit.

Specifications

Spec Value
Part Number 1178001
Type Control / Circuit Board
Brand ICP / Tempstar / Heil
Control Voltage 24 VAC
Function Sequencing, Relay Timing & Safety Control
Fitment OEM Replacement

Compatibility

Direct factory replacement for the ICP WPA4364000RKB1 unit and shared across the ICP brand family — Tempstar, Heil, Comfortmaker, Arcoaire, and KeepRite. Match the board part number and connector layout to your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the control compartment panel.
  3. Document — Photograph every connector and wire harness position before disconnecting.
  4. Remove — Unplug the connectors, release the standoffs/screws, and lift out the old board.
  5. Install — Seat the new board on its standoffs and reconnect every harness exactly per your photo.
  6. Test — Restore power, call for operation, and verify correct sequencing with no fault codes on the diagnostic LED.

Signs You Need a Replacement

  • Unit does not respond to thermostat calls.
  • Diagnostic LED flashing a fault/error code.
  • Erratic cycling or components energizing out of sequence.
  • Visible burn marks, scorched relays, or corrosion on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WPA4364000RKB1 — OEM Circuit Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WPA4364000RKB1 — OEM Circuit Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WPA4364000RKB1 — OEM Circuit Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.