Overview

This is the genuine OEM control circuit board (part number 1178001) for the ICP/Tempstar/Heil WPA4304000RKB1 condensing unit. The control board is the brain of the outdoor unit — it manages the compressor contactor sequence, monitors the high- and low-pressure safety switches, enforces the anti-short-cycle delay, and processes the thermostat call to coordinate cooling operation. When the board fails, symptoms range from a no-cool condition to erratic cycling, ignored safety inputs, or an outdoor unit that simply will not respond to a call even though 24V control power is present. Boards commonly fail from power surges, lightning, moisture intrusion, or burnt relays and traces after a stuck contactor or shorted control circuit.

Specifications

Spec Value
OEM Part Number 1178001
Type Control Circuit Board
Control Voltage 24 VAC
Brand ICP / Tempstar / Heil
Fits Model WPA4304000RKB1

Compatibility

Built as the direct factory replacement for the ICP WPA4304000RKB1 condensing unit and used across ICP-family outdoor units marketed as Tempstar, Heil, Comfortmaker, and Arcoaire. Confirm the printed part number 1178001 and the board's connector and relay layout against your existing board before installing — control boards are model-specific and not interchangeable across platforms.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical access panel to expose the control board.
  3. Document — Photograph every plug, terminal, and wire color before disconnecting.
  4. Remove — Unplug each connector, release the board standoffs or mounting screws, and lift the old board out.
  5. Install — Seat the new board on its standoffs and reconnect every plug and lead exactly per your photo.
  6. Test — Restore power, call for cooling, and verify the board energizes the contactor and the unit runs normally.

Signs You Need a Replacement

  • Outdoor unit will not start despite 24V control power being present.
  • Erratic short-cycling or the compressor running without respecting delays.
  • Visible burnt relays, scorched traces, or corrosion on the board.
  • Safety switches (high/low pressure) are ignored or misread.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WPA4304000RKB1 — OEM Circuit Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WPA4304000RKB1 — OEM Circuit Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WPA4304000RKB1 — OEM Circuit Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.