Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board for WPA4244000RKA1 — OEM Circuit Board | Ships Today
ICP

ICP Control Board for WPA4244000RKA1 — OEM Circuit Board | Ships Today

SKU: 1178001 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM circuit board (part number 1178001) for the ICP WPA4244000RKA1 system. The control board is the brain of the unit — it manages the start-up sequence, timing and anti-short-cycle delays, safety interlocks, fan and compressor relays, and fault diagnostics. It reads the 24V call from the thermostat and energizes the contactor, blower, and other outputs in the correct order. When a control board fails, the system may not respond to the thermostat at all, may run erratically, may lock out on a fault code, or may leave the blower or compressor running continuously. Boards typically fail from power surges, lightning, corrosion, overheated relay contacts, or failed onboard components.

Specifications

Spec Value
OEM Part Number 1178001
Description Circuit Board
Type Control / Logic Board
Brand ICP
Control Voltage 24V
Fits Model WPA4244000RKA1
Fitment OEM Direct Replacement

Compatibility

This circuit board is the factory-specified replacement for the ICP WPA4244000RKA1 and its Tempstar, Heil, and Comfortmaker equivalents. The same board services related ICP WPA-series units — always match the part number 1178001 and the board's connector layout and relay configuration to your original before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage at the board with a multimeter.
  2. Access — Remove the control-box service panel to expose the circuit board.
  3. Document — Photograph every plug, harness, and individual wire location on the board before disconnecting.
  4. Remove — Unplug the harness connectors, release the board standoffs or screws, and lift the old board out.
  5. Install — Seat the new board on the standoffs, then reconnect every connector and wire exactly as shown in your photo.
  6. Test — Restore power, send a call from the thermostat, and confirm the correct start-up sequence with no fault codes.

Signs You Need a Replacement

  • System does not respond to thermostat calls
  • Persistent fault code or hard lockout that returns after reset
  • Blower or compressor runs continuously or cycles erratically
  • Visible burn marks, corrosion, or swollen components on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WPA4244000RKA1 — OEM Circuit Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WPA4244000RKA1 — OEM Circuit Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WPA4244000RKA1 — OEM Circuit Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online