Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board for WPA3484000RKC1 – Defrost Circuit Board | Ships Today
ICP

ICP Control Board for WPA3484000RKC1 – Defrost Circuit Board | Ships Today

SKU: 1178001 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM circuit control board (OEM 1178001) is the electronic brain of the ICP / Heil / Tempstar WPA3484000RKC1 heat pump. It manages the defrost cycle, compressor and fan timing, reversing-valve sequencing, and safety lockouts, coordinating the low-voltage signals from the thermostat with the high-voltage switching of the contactor. When a control board fails, the unit can stop running entirely, get stuck in defrost, ice up in heating mode, short-cycle, or ignore thermostat calls altogether. Burnt traces, scorched relays, swollen components, or a board that no longer energizes the contactor are clear failure signs, often caused by power surges, moisture intrusion, or a shorted control component. Replacing the board with this OEM unit restores proper defrost logic and reliable heat-pump operation.

Specifications

Spec Value
Part Number 1178001
Type Defrost / Sequencing Control Board
Brand ICP / Heil / Tempstar
Function Defrost, timing, and reversing-valve control
Control Voltage 24V

Compatibility

Direct OEM fit for the ICP / Heil / Tempstar WPA3484000RKC1 heat pump condensing unit. Used across ICP-family heat pumps that rely on this defrost control board for compressor and reversing-valve sequencing.

Installation Guide

  1. Safety First – Disconnect power at the breaker and the outdoor disconnect. Verify zero voltage with a multimeter.
  2. Access – Remove the control-panel service cover to reach the board.
  3. Document – Photograph every wire harness, plug, and terminal position on the board before disconnecting.
  4. Remove – Unplug each connector, release the board standoffs or screws, and lift out the failed board.
  5. Install – Seat the new board on the standoffs and reconnect every harness and terminal exactly per your photo.
  6. Test – Restore power and confirm the unit starts, runs, and completes a normal defrost cycle without faults.

Signs You Need a Replacement

  • Unit won't start or ignores thermostat calls
  • Stuck in defrost or icing up in heat mode
  • Short-cycling or erratic compressor and fan operation
  • Visible burnt traces, scorched relays, or swollen components

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WPA3484000RKC1 – Defrost Circuit Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WPA3484000RKC1 – Defrost Circuit Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WPA3484000RKC1 – Defrost Circuit Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online