Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board for WPA3364000RKC1 — OEM Defrost Circuit Board | Ships Today
ICP

ICP Control Board for WPA3364000RKC1 — OEM Defrost Circuit Board | Ships Today

SKU: 1178001 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM circuit board (OEM 1178001) is the electronic brain of the ICP / Tempstar / Heil WPA3364000RKC1 heat pump. It manages the defrost cycle, monitors temperature and pressure inputs, sequences the compressor and reversing valve, and energizes the 24V control circuit that drives the contactor and other components. On a heat pump, the defrost control board is what keeps the outdoor coil clear of ice in heating mode — when it fails, the unit may lock out, run continuously, ice over, or stop heating and cooling altogether. Installing a genuine OEM board restores correct timing and protects the rest of the system.

Specifications

Spec Value
OEM Part Number 1178001
Type Defrost / Control Circuit Board
Brand ICP / Tempstar / Heil
Control Voltage 24 VAC
Function Defrost timing, compressor & reversing valve control
Fits Model WPA3364000RKC1

Compatibility

Direct-fit replacement for the ICP WPA3364000RKC1 heat pump and related Tempstar, Heil, and Comfortmaker units using this control/defrost board. Match the OEM number on your existing board to confirm fitment before installing.

Installation Guide

  1. Safety First — Disconnect power and pull the outdoor disconnect; verify zero voltage with a multimeter.
  2. Access — Remove the control panel cover.
  3. Document — Photograph every connector and wire location on the old board before removing anything.
  4. Remove — Unclip the standoffs/screws and disconnect each harness from the failed board.
  5. Install — Mount the new board and reconnect every connector exactly per your photo, checking the DIP switch / jumper settings match.
  6. Test — Restore power and confirm normal startup, then verify a defrost cycle initiates correctly.

Signs You Need a Replacement

  • Outdoor coil ices over and won't defrost
  • Compressor or fan won't run despite good power
  • Erratic operation, lockouts, or fault codes
  • Visible burnt traces, scorching, or corrosion on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WPA3364000RKC1 — OEM Defrost Circuit Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WPA3364000RKC1 — OEM Defrost Circuit Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WPA3364000RKC1 — OEM Defrost Circuit Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.