Overview

This genuine OEM control board kit (part 1183618) is the electronic brain of the ICP / Tempstar / Heil RHS240L0CA0AAAA heat pump. It sequences the compressor contactor, condenser fan, reversing valve, and defrost cycle, monitoring temperature and timing inputs to protect the system. When a control board fails, the unit may not respond to thermostat calls, get stuck in or skip defrost, short-cycle the compressor, or leave the outdoor fan running at the wrong time. Because the board governs anti-short-cycle and defrost protection, a faulty board can also lead to coil icing and reduced heat-pump efficiency. This kit ships as a complete board assembly ready to drop in.

Specifications

Spec Value
Part Number 1183618
Type Control board kit (defrost/sequencing)
Brand ICP / Tempstar / Heil
Control Voltage 24V
Fitment OEM

Compatibility

Designed for the ICP RHS240L0CA0AAAA heat pump and the RHS240 split-system family marketed under ICP, Tempstar, Heil, and Comfortmaker. Verify the board's connector layout and part number against your existing unit before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and confirm zero voltage with a multimeter.
  2. Access — Remove the condenser control-panel service cover to expose the board.
  3. Document — Photograph every connector, wire color, and terminal position before unplugging anything.
  4. Remove — Unplug the low- and line-voltage harnesses and unclip or unscrew the old board from its standoffs.
  5. Install — Seat the new board on the mounting standoffs and reconnect each harness exactly per your photo.
  6. Test — Restore power, run a heating and a cooling call, and verify proper sequencing, fan operation, and a normal defrost cycle.

Signs You Need a Replacement

  • Unit does not respond to thermostat calls despite good 24V power.
  • Heat pump is stuck in defrost or never defrosts, causing coil ice-up.
  • Compressor short-cycles or the outdoor fan runs at the wrong times.
  • Visible scorching, burnt traces, or failed relays on the existing board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RHS240L0CA0AAAA — OEM Replacement Kit | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RHS240L0CA0AAAA — OEM Replacement Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RHS240L0CA0AAAA — OEM Replacement Kit | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.