Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board for RHS183S0AA0AAAA — 24V Defrost Board Kit | Ships Today
ICP

ICP Control Board for RHS183S0AA0AAAA — 24V Defrost Board Kit | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part 1183618) is the electronic brain of your ICP RHS183S0AA0AAAA heat pump. It manages the defrost cycle, compressor timing, reversing valve operation, and safety interlocks based on inputs from the 24V thermostat and the outdoor coil sensor. When this board fails, the unit may stop defrosting and ice over in heat mode, fail to switch between heating and cooling, short-cycle the compressor, or go completely unresponsive. The kit includes the board and required mounting hardware so you can restore full system control in a single service call. Because the board coordinates nearly every function of the outdoor unit, a marginal board can produce confusing, intermittent symptoms that mimic compressor, contactor, or thermostat faults.

Specifications

Spec Value
OEM Part Number 1183618
Type Defrost / Timing Control Board Kit
Control Voltage 24 VAC
Function Defrost, compressor timing, reversing valve, safeties
Brand ICP / Heil / Tempstar

Compatibility

Built for the ICP RHS183S0AA0AAAA heat pump and used across matching Heil, Tempstar, Comfortmaker, and Day & Night R-410A heat pump platforms. Verify the board layout, connector count, and part number against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the control panel cover to reach the mounted board.
  3. Document — Photograph every plug, wire color, and terminal location before disconnecting.
  4. Remove — Unplug the connectors, release the standoffs or screws, and lift out the old board.
  5. Install — Seat the new board on its standoffs and reconnect each harness exactly per your photo.
  6. Test — Restore power, run a heating and cooling cycle, and confirm proper defrost and changeover operation.

Signs You Need a Replacement

  • Outdoor coil ices over because defrost never initiates.
  • No switching between heating and cooling modes.
  • Compressor short-cycles or will not start.
  • Unit is completely unresponsive to thermostat calls.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RHS183S0AA0AAAA — 24V Defrost Board Kit | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RHS183S0AA0AAAA — 24V Defrost Board Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RHS183S0AA0AAAA — 24V Defrost Board Kit | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online