Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board for RHH060K0XA0AAAA — Defrost Control Kit | Ships Today
ICP

ICP Control Board for RHH060K0XA0AAAA — Defrost Control Kit | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part 1183618) is the electronic brain of the ICP / Heil / Tempstar RHH060K0XA0AAAA heat pump. It manages the defrost cycle, sequences the compressor and outdoor fan, switches the reversing valve through the 24V control circuit, and monitors sensor inputs to protect the system. Supplied as a complete kit with the mounting hardware and connectors needed for a clean swap. Control boards fail from voltage surges, lightning, corrosion on the relays, and simple age — and the symptoms are wide-ranging: no defrost in cold weather (outdoor coil ices over), no changeover between heating and cooling, intermittent operation, blown low-voltage fuses, or a unit that is completely dead despite good incoming power. Because the board ties every major component together, a failing board often masquerades as a bad contactor, sensor, or reversing valve, so confirming the board is a smart move before replacing other parts.

Specifications

Spec Value
OEM Part Number 1183618
Type Defrost / Control Board Kit
Brand ICP / Heil / Tempstar
Control Voltage 24 VAC
Includes Board + mounting hardware
Application Heat Pump

Compatibility

Direct-fit replacement kit for the ICP / Heil / Tempstar RHH060K0XA0AAAA heat pump and shared International Comfort Products platform models (Heil, Tempstar, Comfortmaker, Arcoaire). Match the original board part number before ordering, as board revisions vary by platform.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control-box access panel.
  3. Document — Photograph every wire harness and terminal position on the old board.
  4. Remove — Unplug the harness connectors, release the standoffs/screws, and lift out the old board.
  5. Install — Mount the new board on the supplied standoffs and reconnect each harness exactly per your photo.
  6. Test — Restore power, run a heating and cooling cycle, and confirm defrost initiates and the unit changes over correctly.

Signs You Need a Replacement

  • Outdoor coil ices over with no defrost cycle
  • Unit completely dead with good incoming power
  • No changeover between heating and cooling
  • Repeatedly blown low-voltage fuses or intermittent operation

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RHH060K0XA0AAAA — Defrost Control Kit | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RHH060K0XA0AAAA — Defrost Control Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RHH060K0XA0AAAA — Defrost Control Kit | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online