Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board for RGS303HDAA0AAAA — OEM Kit 1183618 | Ships Today
ICP

ICP Control Board for RGS303HDAA0AAAA — OEM Kit 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part 1183618) is the original-equipment furnace control for the ICP/Tempstar/Heil RGS303HDAA0AAAA. The integrated furnace control board is the brain of the system: it sequences the entire heat cycle — energizing the inducer, proving the pressure switch, firing ignition, opening the gas valve, monitoring flame, and timing the blower on and off. It also runs continuous safety and diagnostic checks and reports faults through its LED flash codes. When the board fails, the furnace can lose ignition entirely, behave erratically, short-cycle, or refuse to run the blower. Symptoms include no response to a thermostat call, blower or inducer that won't start, repeated lockouts with diagnostic flash codes, or visible scorching and burned relays on the board. This kit ships with the OEM board and the hardware needed for a clean replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Control Voltage 24 VAC
Function Ignition Sequencing, Flame Sense, Blower & Safety Timing
Fitment OEM Replacement Kit

Compatibility

Direct OEM replacement kit for the ICP/Tempstar/Heil RGS303HDAA0AAAA furnace and related models in the same family that use control board 1183618. Verify the part number printed on the original board before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control compartment service panel.
  3. Document — Photograph every wire, plug, and terminal on the board before disconnecting anything.
  4. Remove — Unplug the harnesses and spade terminals, unfasten the board standoffs, and lift out the old board.
  5. Install — Mount the new OEM board on its standoffs and reconnect each connector exactly per your photo.
  6. Test — Restore power, run a full heat cycle, and confirm correct sequencing with no fault flash codes.

Signs You Need a Replacement

  • No response from the furnace when the thermostat calls for heat
  • Repeated lockouts or erratic operation with diagnostic flash codes
  • Inducer or blower fails to energize at the right point in the cycle
  • Visible burn marks, scorching, or failed relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS303HDAA0AAAA — OEM Kit 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS303HDAA0AAAA — OEM Kit 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS303HDAA0AAAA — OEM Kit 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online