Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board for RGS240HSAA0AAAA - OEM Furnace Control Kit | Ships Today
ICP

ICP Control Board for RGS240HSAA0AAAA - OEM Furnace Control Kit | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part 1183618) is the integrated furnace control that manages the entire heating and blower sequence on the ICP / Tempstar / Heil RGS240HSAA0AAAA rooftop gas-electric package unit. The board reads the thermostat call, runs the inducer and ignition timing, monitors the limit and pressure safeties, sequences the gas valve and igniter, and times the blower on and off delays. When this board fails you typically see a dead control circuit, repeated ignition lockouts with no clear mechanical cause, blowers that will not start or will not shut off, or a flashing diagnostic LED fault code. The kit ships with the correct firmware, plug layout, and mounting standoffs so it drops into the original harness without rewiring.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Control Voltage 24 VAC
Function Ignition, blower, and safety sequencing
Fit OEM Direct Replacement

Compatibility

Engineered for the ICP-family RGS240HSAA0AAAA packaged rooftop unit and the matching Tempstar, Heil, and Comfortmaker RGS240 builds. Match the printed board number and connector layout against your existing control before ordering.

Installation Guide

  1. Safety First - Disconnect power and verify zero voltage with a multimeter on the line and 24V terminals.
  2. Access - Remove the control-compartment service panel.
  3. Document - Photograph every connector and wire color on the old board before unplugging.
  4. Remove - Unplug each harness connector, release the board standoffs or screws, and remove the old board.
  5. Install - Seat the new board on its standoffs and reconnect each harness to the matching plug per your photo.
  6. Test - Restore power and confirm a full heat cycle - inducer, ignition, gas valve, and blower - with no fault code.

Signs You Need a Replacement

  • No response at all on a heating or cooling call.
  • Repeated ignition lockouts with no mechanical fault found.
  • Blower that will not start or will not shut off.
  • Flashing diagnostic LED reporting a control or internal fault.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS240HSAA0AAAA - OEM Furnace Control Kit | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS240HSAA0AAAA - OEM Furnace Control Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS240HSAA0AAAA - OEM Furnace Control Kit | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online