Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board for RGS214HDGHAACAA — Integrated Furnace Reheat Circuit Board | Ships Today
ICP

ICP Control Board for RGS214HDGHAACAA — Integrated Furnace Reheat Circuit Board | Ships Today

SKU: 1186501 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board is the electronic brain of your ICP / Tempstar / Heil RGS214HDGHAACAA gas furnace package unit. It manages the ignition sequence, blower timing, safety lockouts, and reheat operation, coordinating the igniter, gas valve, pressure switches, and blower motor on every call for heat. Sold here are the genuine circuit board reheat (part 1186501) and control board kit (part 1183618). When this board fails you will typically see no ignition, short cycling, the blower running continuously, or an LED fault/flash code that will not clear. Because the board governs every safety interlock, a failing board should be replaced with a genuine OEM unit rather than a generic substitute.

Specifications

Spec Value
Part Number 1186501 (Circuit Board Reheat), 1183618 (Kit Control Board)
Type Integrated Furnace Control Board
Brand ICP / Tempstar / Heil / Comfortmaker
Control Voltage 24V
Fits Model RGS214HDGHAACAA
Fit OEM Replacement

Compatibility

Engineered as a direct-fit replacement for the ICP RGS214HDGHAACAA gas furnace package unit and shared chassis sold under the Tempstar, Heil, and Comfortmaker labels. Always match your existing board part number and connector layout before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, verify zero voltage with a multimeter, and shut off the gas supply.
  2. Access — Remove the control/blower service panel.
  3. Document — Photograph every wire and connector position before disconnecting anything.
  4. Remove — Label and unplug each harness, then remove the mounting screws or standoffs holding the old board.
  5. Install — Mount the new board, reconnect every harness exactly per your photos, and confirm dip-switch/jumper settings match the original.
  6. Test — Restore gas and power, initiate a heat call, and confirm a clean ignition, proper blower timing, and no fault codes.

Signs You Need a Replacement

  • Furnace will not ignite or has no response on a call for heat.
  • Blower runs continuously or fails to start.
  • Short cycling or repeated safety lockouts.
  • Diagnostic LED shows a hard fault code or no light at all.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS214HDGHAACAA — Integrated Furnace Reheat Circuit Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS214HDGHAACAA — Integrated Furnace Reheat Circuit Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS214HDGHAACAA — Integrated Furnace Reheat Circuit Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online