Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board for RGS150LDAA0AAAA — OEM Kit 1183618 | Ships Today
ICP

ICP Control Board for RGS150LDAA0AAAA — OEM Kit 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The ICP control board kit (OEM part 1183618) is the integrated furnace control (IFC) that manages ignition sequencing, blower timing, gas valve operation, and safety lockouts for your ICP/Tempstar/Heil RGS150LDAA0AAAA gas furnace. It is the central electronic brain of the unit: it reads the thermostat call, energizes the inducer, verifies pressure-switch closure, fires the igniter, opens the gas valve, and proves flame before staging the blower. When this board fails, the furnace typically will not start, locks out after a few ignition attempts, or short-cycles unpredictably. Common failure symptoms include a furnace that hums but never ignites, a blinking diagnostic LED indicating a control fault, no response to a thermostat call, or relays that chatter. This factory kit includes the board and the mounting/wiring hardware needed for a direct replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Function Ignition, blower, gas valve & safety control
Fitment OEM direct replacement

Compatibility

Engineered for the ICP / Tempstar / Heil model RGS150LDAA0AAAA gas furnace and its sister units that originally shipped with control board 1183618. Always confirm the part number printed on your existing board before ordering, as ICP used several board revisions across this platform.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment service panel.
  3. Document — Photograph every wire and connector on the existing board before disconnecting anything.
  4. Remove — Unplug the harness connectors and low-voltage terminals, then unscrew the failed board from its standoffs.
  5. Install — Mount the new board, transfer each connector to the matching terminal per your photos, and confirm DIP switch settings match the original.
  6. Test — Restore power, initiate a heat call, and confirm a full ignition sequence and proper blower operation.

Signs You Need a Replacement

  • Furnace will not respond to a thermostat heat call.
  • Repeated ignition lockouts or a hard-lockout diagnostic LED code.
  • Blower or inducer relays chatter, stick, or fail to energize.
  • Visible burn marks, scorched traces, or a cracked board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS150LDAA0AAAA — OEM Kit 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS150LDAA0AAAA — OEM Kit 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS150LDAA0AAAA — OEM Kit 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online