Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board for RGS120SFAA0AAA — Integrated Furnace Ignition Control | Ships Today
ICP

ICP Control Board for RGS120SFAA0AAA — Integrated Furnace Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The OEM control board kit (part number 1183618) is the electronic brain of your ICP RGS120SFAA0AAA gas furnace. It manages the entire heating sequence — call for heat, inducer start, hot surface igniter timing, gas valve energizing, flame sensing, and blower on/off delays — while continuously monitoring safety limits and pressure switches. When this board fails, the furnace may fail to ignite, short-cycle, lock out after a few attempts, run the blower continuously, or flash a diagnostic fault code. A board that is cracked, has burnt traces, blown relays, or corroded connectors should be replaced rather than repaired.

Specifications

Spec Value
Part Number 1183618 (KIT CONTROL BOARD)
Type Integrated furnace control board
Brand ICP / Heil / Tempstar / Comfortmaker
Control Voltage 24V
Fitment OEM direct replacement

Compatibility

Engineered as a direct OEM replacement for the ICP RGS120SFAA0AAA gas furnace and other compatible models across the ICP family of brands (Heil, Tempstar, Comfortmaker). Always match your existing board part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower-compartment service panel.
  3. Document — Photograph every wire and connector position on the old board before disconnecting anything.
  4. Remove — Unplug all harness connectors, remove the mounting screws/standoffs, and lift out the failed board.
  5. Install — Mount the new board, then reconnect every harness exactly as photographed.
  6. Test — Restore power, initiate a call for heat, and confirm a full ignition cycle with proper blower operation.

Signs You Need a Replacement

  • Furnace will not ignite or repeatedly locks out
  • Diagnostic LED flashing an error / no LED at all
  • Blower runs constantly or never engages
  • Visible burnt spots, cracked traces, or failed relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS120SFAA0AAA — Integrated Furnace Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS120SFAA0AAA — Integrated Furnace Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS120SFAA0AAA — Integrated Furnace Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online