This OEM Integrated Furnace Control (IFC) board, ICP part number 1183618, is the electronic brain of your ICP/Heil/Tempstar RGS102HFBA0AAA gas furnace. It manages ignition sequencing, blower and inducer timing, flame sensing, and built-in safety lockouts on a nominal 24V control circuit. When this board fails the furnace may fail to ignite, short-cycle, run the blower continuously, or flash a diagnostic fault code on its onboard LED. Replacing the board with a genuine OEM control restores reliable, code-correct operation and preserves the factory diagnostic LED behavior technicians rely on.

Specifications

Spec Value
Part Number 1183618 (KIT CONTROL BOARD)
Type Integrated Furnace Control (IFC)
Brand ICP / Heil / Tempstar
Control Voltage 24V
Function Ignition, blower & inducer timing, flame sense, safety lockout
Fitment OEM direct replacement

Compatibility

Engineered as a direct-fit replacement for the ICP/Heil/Tempstar RGS102HFBA0AAA furnace and shared-platform models that originally used control board 1183618. Always confirm your existing board's part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph every wire and connector position before disconnecting anything.
  4. Remove — Unplug the wiring harnesses, release the board mounting screws/standoffs, and lift the old control out.
  5. Install — Mount the new board, reconnect each harness exactly per your photos, and set any DIP switches to match the original.
  6. Test — Restore power and run a full heat cycle; confirm ignition, blower delay, and a steady (no-fault) diagnostic LED.

Signs You Need a Replacement

  • Furnace will not ignite or locks out repeatedly
  • Blower or inducer runs continuously or won't start
  • Erratic short-cycling or no response to thermostat calls
  • Diagnostic LED flashing a hard-fault or control-failure code

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102HFBA0AAA — Integrated Furnace Control Kit | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102HFBA0AAA — Integrated Furnace Control Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102HFBA0AAA — Integrated Furnace Control Kit | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online