Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor Set for RGS303HEAA0AAAA — 2-Pole 30A & 3-Pole 60A, 24V Coil | Ships Today
ICP

ICP Contactor Set for RGS303HEAA0AAAA — 2-Pole 30A & 3-Pole 60A, 24V Coil | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM contactor set fits the ICP Tempstar Heil RGS303HEAA0AAAA and switches high-voltage power to the compressor and fan loads on a 24V control signal. It includes the 2-pole 30-amp contactor (OEM 1171554) and the 3-pole 60-amp contactor (OEM 1183142), both with 24V coils. A contactor is an electromagnetic switch: when the thermostat calls, 24V energizes the coil, pulling the contacts closed to deliver line voltage to the load. Pitted, welded, or chattering contacts cause hard starts, no-cool/no-run conditions, or a system that won't shut off. Replacing with the correct OEM contactor restores clean, reliable switching and protects downstream components.

Specifications

Spec Value
Part Numbers 1171554, 1183142
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
2-Pole Rating 30A
3-Pole Rating 60A
Coil Voltage 24 VAC
Fit OEM Replacement

Compatibility

Built for the ICP Tempstar Heil RGS303HEAA0AAAA and related ICP/Heil/Tempstar/Comfortmaker systems using 24V-coil definite-purpose contactors. Confirm pole count, amp rating, and coil voltage against your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the electrical service panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Pull the wires, unscrew the old contactor from its mounting rail or bracket.
  5. Install — Mount the new OEM contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, place a call, and confirm the contactor pulls in cleanly and switches the load.

Signs You Need a Replacement

  • System fails to start or only runs intermittently
  • Loud chattering or humming from the contactor
  • Pitted, burnt, or welded contacts
  • Unit continues running after the call ends

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS303HEAA0AAAA — 2-Pole 30A & 3-Pole 60A, 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS303HEAA0AAAA — 2-Pole 30A & 3-Pole 60A, 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS303HEAA0AAAA — 2-Pole 30A & 3-Pole 60A, 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online