Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor Set 30A 40A 60A 24V Coil for RHS243H0EA0AAAA | Ships Today
ICP

ICP Contactor Set 30A 40A 60A 24V Coil for RHS243H0EA0AAAA | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

OEM definite-purpose contactors for the ICP / Heil / Tempstar RHS243H0EA0AAAA heat pump, all using a 24VAC control coil. This listing covers the 2-pole 30A contactor (P/N 1171554), the 3-pole 40A contactor (P/N 1172449), and the 3-pole 60A contactor (P/N 1183142). The contactor is the heavy-duty switch that closes line voltage to the compressor and outdoor fan motor whenever the thermostat energizes the 24V coil. Pitted, welded, or chattering contacts are one of the most common reasons a condenser won't start, hums without running, or short-cycles.

Specifications

Spec Value
2-Pole 30A P/N 1171554
3-Pole 40A P/N 1172449
3-Pole 60A P/N 1183142
Type Definite Purpose Contactor
Brand ICP / Heil / Tempstar / Comfortmaker
Coil Voltage 24 VAC
Contact Rating 30A / 40A / 60A
Poles 2-Pole & 3-Pole
Application Compressor & Condenser Fan Switching

Compatibility

Designed for the ICP-family RHS243H0EA0AAAA heat pump. Match your replacement to the pole count, amp rating, and 24V coil of the original contactor. The same definite-purpose footprint fits a wide range of Heil, Tempstar, and Comfortmaker condensing units.

Installation Guide

  1. Safety First - Kill power at the disconnect and breaker, then verify zero voltage across the line terminals with a multimeter.
  2. Access - Remove the condenser service panel to reach the contactor.
  3. Document - Photograph every line, load, and coil wire before removal.
  4. Remove - Loosen the terminal screws, transfer one wire at a time, and unscrew the old contactor from its bracket.
  5. Install - Mount the new contactor, torque each lead to spec, and confirm the 24V coil leads land on the A1/A2 terminals.
  6. Test - Restore power and verify a crisp pull-in click and full contact closure on a cooling call.

Signs You Need a Replacement

  • Loud humming or buzzing with no compressor start
  • Burned, pitted, or welded contact points
  • Chattering or rapid on/off cycling of the outdoor unit
  • Coil that won't pull the contacts in on a 24V signal

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS243H0EA0AAAA | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS243H0EA0AAAA | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS243H0EA0AAAA | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online