OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
These OEM definite-purpose contactors fit the ICP/Tempstar/Heil RGS213HTAA0AAAA: a 2-pole 30-amp unit (part 1171554) and a 3-pole 40-amp unit (part 1172449), both with a 24-volt control coil. A contactor is the high-current switch that delivers line voltage to the compressor and condenser fan motor whenever the thermostat energizes the 24V coil. Over thousands of cycles the contacts arc, pit, and carbon up, leading to a system that hums but won't start, buzzes loudly, chatters, or fails to shut off because the contacts have welded closed. Installing a fresh OEM contactor restores clean, full-voltage switching to the outdoor unit.
| Spec | Value |
|---|---|
| Part Numbers | 1171554 (2P 30A), 1172449 (3P 40A) |
| Type | Definite-Purpose Contactor |
| Poles | 2-Pole / 3-Pole |
| Contact Rating | 30A / 40A |
| Coil Voltage | 24V |
| Brand | ICP / Tempstar / Heil |
| Fit | OEM Replacement |
Fits the ICP/Tempstar/Heil RGS213HTAA0AAAA and related RGS213 series equipment. Match your existing contactor's pole count (2 or 3), amp rating (30A or 40A), and 24V coil before ordering.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.