These OEM definite-purpose contactors fit the ICP/Tempstar/Heil RGS213HTAA0AAAA: a 2-pole 30-amp unit (part 1171554) and a 3-pole 40-amp unit (part 1172449), both with a 24-volt control coil. A contactor is the high-current switch that delivers line voltage to the compressor and condenser fan motor whenever the thermostat energizes the 24V coil. Over thousands of cycles the contacts arc, pit, and carbon up, leading to a system that hums but won't start, buzzes loudly, chatters, or fails to shut off because the contacts have welded closed. Installing a fresh OEM contactor restores clean, full-voltage switching to the outdoor unit.

Specifications

Spec Value
Part Numbers 1171554 (2P 30A), 1172449 (3P 40A)
Type Definite-Purpose Contactor
Poles 2-Pole / 3-Pole
Contact Rating 30A / 40A
Coil Voltage 24V
Brand ICP / Tempstar / Heil
Fit OEM Replacement

Compatibility

Fits the ICP/Tempstar/Heil RGS213HTAA0AAAA and related RGS213 series equipment. Match your existing contactor's pole count (2 or 3), amp rating (30A or 40A), and 24V coil before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage across all line terminals with a multimeter.
  2. Access — Remove the outdoor unit electrical access panel.
  3. Document — Photograph every line, load, and coil wire before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unscrew the old contactor from its base.
  5. Install — Mount the new contactor, reconnect each wire to the matching terminal per your photo, and torque the lugs.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but won't start
  • Contactor chatters or won't pull in on a cooling call
  • System won't shut off (welded contacts)
  • Burnt, pitted, or corroded contact surfaces

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS213HTAA0AAAA | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS213HTAA0AAAA | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS213HTAA0AAAA | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.