Overview

These OEM definite-purpose contactors switch line-voltage power to the compressor and condenser fan on the ICP RHS243S0FA0AAAA heat pump. A contactor is an electrically operated switch: a 24V signal from the thermostat/control energizes the contactor coil, which closes the high-current contacts and powers the compressor and fan. Two options cover this platform — part 1171554, a 2-pole 30A contactor with a 24V coil, and part 1172449, a 3-pole 40A contactor with a 24V coil. Contacts are wear items; arcing slowly pits and burns them until they no longer close cleanly. A failing contactor causes the outdoor unit to fail to start, chatter or buzz, weld its contacts closed (unit won't shut off), or short-cycle.

Specifications

Spec Value
Part Numbers 1171554 (2P 30A), 1172449 (3P 40A)
Type Definite Purpose Contactor
Brand ICP
Poles 2-Pole or 3-Pole
Contact Rating 30A (2P) / 40A (3P)
Coil Voltage 24V
Fits Model RHS243S0FA0AAAA

Compatibility

Designed for the ICP RHS243S0FA0AAAA and equivalent Tempstar, Heil, and Comfortmaker condensing units. Match the pole count (2 or 3), amperage, and 24V coil rating to the contactor currently installed in your unit.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser unit's electrical access panel.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Disconnect all leads and unfasten the old contactor from its mounting feet.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a call and the compressor/fan start.

Signs You Need a Replacement

  • Outdoor unit won't start on a cooling or heating call
  • Loud buzzing or chattering from the contactor
  • Pitted, burned, or welded contacts (unit runs continuously)
  • Visible arcing or melted contactor housing

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS243S0FA0AAAA — OEM 1171554 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS243S0FA0AAAA — OEM 1171554 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS243S0FA0AAAA — OEM 1171554 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.