Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor Kit for RHS181L0AA0AAAA — 2-Pole 30A & 3-Pole 40A 24V Coil | Ships Today
ICP

ICP Contactor Kit for RHS181L0AA0AAAA — 2-Pole 30A & 3-Pole 40A 24V Coil | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM contactor kit for the ICP/Tempstar/Heil RHS181L0AA0AAAA heat pump includes the 1171554 2-pole 30-amp contactor and the 1172449 3-pole 40-amp contactor, both with a 24V control coil. The contactor is the high-voltage switch that energizes the compressor and condenser fan whenever the 24V control circuit calls. Contactors wear out from arcing — the contacts pit and weld, or the coil burns open. Symptoms include a unit that hums but won't start, contacts that stick closed so the compressor never shuts off, or no power to the compressor at all. Genuine OEM contactors match the exact amp and coil ratings for safe, reliable switching.

Specifications

Spec Value
Part Number (2-Pole) 1171554 — 2P 30A
Part Number (3-Pole) 1172449 — 3P 40A
Type Definite-purpose contactor
Brand ICP / Tempstar / Heil
Coil Voltage 24V
Amp Ratings 30A (2P) / 40A (3P)
Poles 2-pole and 3-pole
Fits Model RHS181L0AA0AAAA

Compatibility

Fits the ICP/Tempstar/Heil RHS181L0AA0AAAA and related RHS181 series condensing units. Match the pole count and amp rating (2-pole 30A or 3-pole 40A) to the contactor currently installed in your unit.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect; verify zero voltage with a multimeter.
  2. Access — Remove the electrical-box service panel.
  3. Document — Photograph the line, load, and 24V coil wiring before disconnecting.
  4. Remove — Release the mounting screws and transfer wires off the old contactor.
  5. Install — Mount the new contactor and land each wire exactly per your photo, including the 24V coil leads.
  6. Test — Restore power and confirm the contactor pulls in on a call and drops out when satisfied.

Signs You Need a Replacement

  • Unit hums or buzzes but compressor won't start
  • Contacts welded closed — compressor never shuts off
  • Pitted, burnt, or corroded contact surfaces
  • Open 24V coil — no pull-in on a thermostat call

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS181L0AA0AAAA — 2-Pole 30A & 3-Pole 40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS181L0AA0AAAA — 2-Pole 30A & 3-Pole 40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS181L0AA0AAAA — 2-Pole 30A & 3-Pole 40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online