Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor for YK030G1 — 1-Pole 25A 24V Coil | Ships Today
ICP

ICP Contactor for YK030G1 — 1-Pole 25A 24V Coil | Ships Today

SKU: 1050699 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole definite purpose contactor (part number 1050699) is the electrically operated switch that energizes the compressor and condenser fan in your ICP / Heil / Tempstar YK030G1 condensing unit. When the thermostat calls, the 24V control circuit pulls in the contactor coil, closing 25-amp line-voltage contacts that power the outdoor unit. After tens of thousands of cycles the contact points pit, arc, and erode, so the unit can no longer start reliably — or the contacts weld shut and the compressor runs continuously. A loud buzzing or chattering outdoor unit, a contactor that won't pull in, or burned and pitted contacts all point to a worn contactor. It is one of the most common HVAC failures and one of the quickest, most affordable to fix.

Specifications

Spec Value
OEM Part Number 1050699
Type Definite Purpose Contactor
Poles 1 (Single Pole)
Contact Rating 25 Amps
Coil Voltage 24V
Brand ICP (Heil / Tempstar / Comfortmaker)
Fits Model YK030G1

Compatibility

A direct OEM replacement for the ICP YK030G1 condensing unit and shared across compatible Heil, Tempstar, and Comfortmaker heat pumps and air conditioners that use a 1-pole 25A 24V-coil contactor. Confirm amp rating, pole count, and coil voltage before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage across the contactor terminals with a multimeter.
  2. Access — Remove the electrical service panel on the condensing unit.
  3. Document — Photograph every wire and terminal position before disconnecting.
  4. Remove — Label and disconnect the line, load, and 24V coil leads, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo with tight connections.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the unit starts.

Signs You Need a Replacement

  • Loud buzzing, humming, or chattering from the outdoor unit
  • Contactor fails to pull in on a thermostat call
  • Pitted, burned, or melted contact points
  • Compressor runs nonstop from welded-shut contacts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YK030G1 — 1-Pole 25A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YK030G1 — 1-Pole 25A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YK030G1 — 1-Pole 25A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online