Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor for YJ048GB1 — 1-Pole 35A 24V | Ships Today
ICP

ICP Contactor for YJ048GB1 — 1-Pole 35A 24V | Ships Today

SKU: 1050839 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 1-pole 35-amp definite-purpose contactor with a 24V coil (ICP part number 1050839) for the ICP YJ048GB1 heat pump. The contactor is the high-current relay that switches line voltage to the compressor and condenser fan whenever the 24V control circuit calls for operation. Over years of cycling, the contacts pit, burn, or weld, and the coil can fail — leaving the outdoor unit dead, chattering, or unable to drop out when the call ends.

Specifications

Spec Value
Part Number 1050839
Type Definite-Purpose Contactor
Brand ICP
Poles 1-Pole
Contact Rating 35 Amps
Coil Voltage 24 VAC
Application Compressor / Condenser Fan

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil YJ048GB1 heat pump. Confirm the 1-pole configuration, 35A contact rating, and 24V coil against your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the condenser control-box panel to expose the contactor.
  3. Document — Photograph every line, load, and 24V coil connection before disconnecting.
  4. Remove — Transfer wires one at a time, or label them, then unscrew the old contactor from its mounting bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo, confirming line and load on the correct poles.
  6. Test — Restore power and confirm the contactor pulls in on a call and drops out cleanly when satisfied.

Signs You Need a Replacement

  • Outdoor unit will not start on a cooling/heating call
  • Loud buzzing or chattering at the contactor
  • Pitted, burned, or welded contacts
  • Compressor keeps running after the call ends

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YJ048GB1 — 1-Pole 35A 24V | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YJ048GB1 — 1-Pole 35A 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YJ048GB1 — 1-Pole 35A 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online